<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "journalpublishing.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="2.0" xml:lang="en" article-type="reviewer-report"><front><journal-meta><journal-id journal-id-type="nlm-ta">JMIRx Med</journal-id><journal-id journal-id-type="publisher-id">xmed</journal-id><journal-id journal-id-type="index">34</journal-id><journal-title>JMIRx Med</journal-title><abbrev-journal-title>JMIRx Med</abbrev-journal-title><issn pub-type="epub">2563-6316</issn><publisher><publisher-name>JMIR Publications</publisher-name><publisher-loc>Toronto, Canada</publisher-loc></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">v7i1e111437</article-id><article-id pub-id-type="doi">10.2196/111437</article-id><article-categories><subj-group subj-group-type="heading"><subject>Peer-Review Report</subject></subj-group></article-categories><title-group><article-title>Peer Review of &#x201C;AI-Driven and Automated Systems for Continuous Oxygen Saturation Monitoring in Long-Term Oxygen Therapy: Systematic Review&#x201D;</article-title></title-group><contrib-group><contrib contrib-type="author"><name name-style="western"><surname>Lee</surname><given-names>Juhee</given-names></name><xref ref-type="aff" rid="aff1"/></contrib></contrib-group><aff id="aff1"><institution>Yonsei University College of Nursing</institution><addr-line>Seoul</addr-line><country>Republic of Korea</country></aff><contrib-group><contrib contrib-type="editor"><name name-style="western"><surname>Schwartz</surname><given-names>Amy</given-names></name></contrib></contrib-group><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>7</day><month>10</month><year>2026</year></pub-date><volume>7</volume><elocation-id>e111437</elocation-id><history><date date-type="received"><day>07</day><month>09</month><year>2026</year></date><date date-type="accepted"><day>07</day><month>09</month><year>2026</year></date></history><copyright-statement>&#x00A9; Juhee Lee Originally published in JMIRx Med (<ext-link ext-link-type="uri" xlink:href="https://med.jmirx.org">https://med.jmirx.org</ext-link>), 7.10.2026. </copyright-statement><copyright-year>2026</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIRx Med, is properly cited. The complete bibliographic information, a link to the original publication on <ext-link ext-link-type="uri" xlink:href="https://med.jmirx.org/">https://med.jmirx.org/</ext-link>, as well as this copyright and license information must be included.</p></license><self-uri xlink:type="simple" xlink:href="https://xmed.jmir.org/2026/1/e111437"/><related-article related-article-type="companion" ext-link-type="doi" xlink:href="10.1101/2025.04.20.25326131v1" xlink:title="Preprint (medRxiv)" xlink:type="simple">https://www.medrxiv.org/content/10.1101/2025.04.20.25326131v1</related-article><related-article related-article-type="companion" ext-link-type="doi" xlink:href="10.2196/76506" xlink:title="Preprint (JMIR Preprint)" xlink:type="simple">http://preprints.jmir.org/preprint/76506</related-article><related-article related-article-type="companion" ext-link-type="doi" xlink:href="10.2196/111441" xlink:title="Authors' Response to Peer-Review Reports" xlink:type="simple">https://med.jmirx.org/2026/1/e111441</related-article><related-article related-article-type="companion" ext-link-type="doi" xlink:href="10.2196/76506" xlink:title="Published Article" xlink:type="simple">https://med.jmirx.org/2026/1/e76506</related-article><kwd-group><kwd>long-term oxygen therapy</kwd><kwd>artificial intelligence</kwd><kwd>machine learning</kwd><kwd>oxygen saturation monitoring</kwd><kwd>pulse oximetry</kwd><kwd>closed-loop systems</kwd><kwd>automated oxygen titration</kwd><kwd>motion artifacts</kwd><kwd>chronic obstructive pulmonary disease</kwd><kwd>systematic review</kwd></kwd-group></article-meta></front><body><p><italic>This is a peer-review report for &#x201C;AI-Driven and Automated Systems for Continuous Oxygen Saturation Monitoring in Long-Term Oxygen Therapy: Systematic Review.&#x201D;</italic></p><sec id="s2"><title>Round 1 Review</title><sec id="s1-1"><title>Specific Comments</title><sec id="s1-1-1"><title>Major Comments</title><p>This paper [<xref ref-type="bibr" rid="ref1">1</xref>] aims to evaluate AI-based and automated systems for long-term oxygen therapy (LTOT), addressing a timely and clinically relevant topic given the rapid advancement in personalized and responsive respiratory care technologies. The systematic approach and effort to integrate performance and usability dimensions are commendable. However, in its current form, the manuscript requires substantial revisions before it can be considered for publication. In particular, I would like to highlight the following concerns.</p><p>1. Lack of clearly defined research goal and review question.</p><p>The research goal and review question are not clearly described. This makes it difficult to understand whether the review is meant to summarize existing technologies, compare the performance of AI and automated systems, or evaluate how these systems can be applied in real clinical settings.</p><p>2. Insufficient background on technological context and rationale.</p><p>In the Introduction section, the paper should provide more background to help readers understand why the new approach is important. It should briefly explain how LTOT technology has changed over time, what makes AI-based systems different, and why this review is timely and needed. While the Introduction mentions some clinical problems that AI aims to solve&#x2014;such as inefficiency of fixed flow and poor response to activity changes&#x2014;it does not explain how older technologies tried to handle these issues or where they fell short.</p><p>3. Misalignment between stated objectives and inclusion criteria.</p><p>Although the Introduction emphasizes the need for a comprehensive review of AI technologies in the context of LTOT, the actual inclusion criteria are limited to studies addressing technical challenges such as motion-induced signal distortions (eg, convolutional neural network&#x2013;based denoising, wavelet transforms), low-perfusion signal management, mitigation of skin tone&#x2013;related measurement bias, and signal stability over 24 hours.</p><p>4. Unclear populations in reviewed studies.</p><p>The manuscript does not clearly describe which patient populations were included in the evaluation of AI or automated systems. Without this information, it is difficult to assess the clinical relevance and generalizability of the findings. Given that LTOT is most commonly used in older adult or chronic obstructive pulmonary disease populations, it is essential to specify whether the reviewed studies included such groups, especially in real-world or home-care settings.</p></sec><sec id="s1-1-2"><title>Minor Comments</title><p>1. Please consider expanding the summary table to include more descriptive information (for example, publication year and country, participant characteristics, and study design). Also, to reduce confusion, organize key system outputs such as SpO<sub>&#x2082;</sub> accuracy, motion artifact handling, and skin tone bias under a single &#x201C;Outcomes&#x201D; category rather than listing them individually.</p><p>2. Abbreviations should be written out in full only once when first introduced. There is no need to repeat the full terms (abbreviations) in later sections such as the Discussion or Future Directions section.</p></sec></sec></sec></body><back><ref-list><title>References</title><ref id="ref1"><label>1</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kadariya</surname><given-names>S</given-names> </name><name name-style="western"><surname>Niraula</surname><given-names>P</given-names> </name><name name-style="western"><surname>Poudel</surname><given-names>B</given-names> </name><name name-style="western"><surname>Kadariya</surname><given-names>S</given-names> </name></person-group><article-title>AI-driven and automated systems for continuous oxygen saturation monitoring in long-term oxygen therapy: systematic review</article-title><source>JMIRx Med</source><year>2026</year><volume>7</volume><fpage>e76506</fpage><pub-id pub-id-type="doi">10.2196/76506</pub-id></nlm-citation></ref></ref-list></back></article>